Coming up on this week's news. A court fines an NICEIC contractor over electrical safety certs for dangerous installations. A fire that killed a mother and her two children in Gloucestershire is blamed on electrical appliances. And hackers gain control of fridges and freezers. What it means for control systems moving forward.
Welcome to Electrical News Weekly, whether you're listening in the van, on site, or down at the wholesale counter. I'm Joe Robinson and I've been through the best of the electrical industry news to save you the trouble.
We're being lit by Flex7 with their lightning-fast, pre-wired modular lighting connection system that keeps your installation times razor sharp.
And if you think you've spotted the two words that I've been challenged to slip into this week's show, comment with them below for the chance to win this exclusive cap branded with friends of the show Quickwire and Chumptools. And while you're there, click the link to our show notes to check out what our sponsors offer. And stay tuned to the end of the show to catch up on our regular features, including the weather from Fox ESS, the lighter side of the news with Quickwire, and Learner of the Week in association with Dovetail and Slate.
A court has fined an NICEIC contractor £20,000 for providing electrical safety certificates for two dangerous installations in Runcorn. Epco Energy Solutions Limited, who were at the time members of the NICEIC, supplied the certs for two car wash businesses despite them both being declared unsafe.
The prosecution followed a swoop on Super Hand Car Wash on Halton Road and Top Star Hand Car Wash on Bridge Street by the health and safety investigators in a joint operation with Cheshire Police, Trading Standards and the immigration authorities. Both operations were found to have electrical systems that were dangerous and were shut down. A subsequent examination of the certs found that the details in them did not match the actual installations. Despite being given a clean bill of health, the enterprises presented a risk of serious injury or electrocution to those on site, including members of the public.
Epco Energy Solutions Limited had visited and provided electronically generated certificates using the NICEIC secure members-only systems. Certificates provided to the car washes indicated that the electrical systems on site were safe to use when they were not. With support from the NICEIC, it was found that the certificates had been generated using password-protected software and electronically signed with the signature of the sole Epco director, Mohammed Naeem. Epco Energy Solutions Limited, of Unit B, 37 Worsley Road, Eccles, Manchester, was found guilty at Warrington Magistrates' Court of breaching the Health and Safety at Work Act, was fined £20,000 and ordered to pay full costs of over £15,000. HSE inspector Rose Leese-Weller told the press that because car washes have such a close relationship with water, owners must ensure that their electrical installations are maintained in a safe condition.
And if you're slightly more responsible with your EICRs, then check out TestFast. It's built to give thorough, comprehensive electrical installation condition reports without spending hours at the laptop. From clever features like automated schedules from scans of consumer units to scribbled notes converted into perfectly coded BS 7671 defects, it's designed to give you your evenings back. Click the link in the show notes for more information.
Meanwhile, a coroner's court in Gloucestershire has heard that a fire that killed a mother, two children, and the family dog on Boxing Day was probably caused by electrical items connected to the mains power supply. Fionnghuala Shearman, known as Nu, died alongside her children Eve, seven, and four-year-old Ohner, and dog Hutch. The inquest heard that Fionnghuala's husband Tom Shearman tried to reach the children in their bedroom by striking and kicking a window from outside the house, but was unable to gain access.
Because of the severity of the blaze, Mr Shearman failed to regain entry through the bathroom window and could not force open the ground-floor doors despite sustaining significant injuries in the process.
Leroy Hughes, station manager for Gloucestershire Fire and Rescue Service, said an investigation into the incident led him to believe it had started in the living room before spreading throughout the house. Its likely origin was with electrical devices connected to the domestic power supply.
Coroner Katy Skerrett paid tribute to Mr Shearman's valiant attempts to save his family. She concluded that these were accidental deaths, describing it as an absolute tragedy with the most horrific consequences possible for this loving young family.
Such a tragic story that one.
In other news, concerns in the trade over internet-connected electrical equipment has risen sharply following recent cyberattacks against supermarkets. Hackers, believed to be Iranian, took control of fridges and freezers and remotely cranked up the temperatures in a move that proved even less popular than microplastics in water supplies. Retailers were forced to throw away millions of pounds worth of spoiled food.
The incident raised many questions for contractors involved in designing, building or installing control panels. Just how secure are the systems we're connecting to the outside world?
Now, new European rules due in a number of weeks are set to raise the bar on installs. The new EU Machinery Regulation comes into force on 20 January 2027, replacing the existing Machinery Directive.
For the first time, the law explicitly addresses the threat of malicious interference with control systems. It requires manufacturers to protect safety-related functions against corruption and unauthorised access. That has important implications for machinery manufacturers and control-panel builders supplying equipment into the European market.
And it isn't just about stopping hackers getting in. It's about making sure that a cyber attack can't compromise the safety functions of an installation.
My eFIXX colleague Gordon has taken a closer look at what the new rules mean for electrical control panels and what manufacturers and panel builders need to do to prepare. I'll put a link to the full explainer in the show notes.
Experts from the IET have stepped in to help the trade get its head around one of the most feared calculations in the wiring regulations: the dreaded adiabatic equation. You won't find this being taught in kindergarten. The equation, contained in Regulation 543.1.3 of BS 7671, is used to calculate the minimum cross-sectional area of a protective conductor needed to withstand the thermal effects of a fault current without suffering damage. But it famously stumps many sparks.
But now, IET engineer Michael Peace has stepped up with an explainer that aims to demystify the calculation. First, he says the word adiabatic means no heat transfer to the surroundings, because switchgear trips so fast there isn't time for heat to be transferred. He goes on to show how you should establish the three key values: the fault current I, the disconnection time t, and the conductor material factor k.
Peace also busts a common myth about the equation, that the disconnection time used is simply the maximum permitted by the regulations. It's not. Instead, it must be the actual operating time corresponding to the calculated fault current.
The guidance includes worked examples using a 32 A BS 88-3 fuse and a Type B circuit-breaker, and explains when manufacturers' energy let-through data must be used instead. It also highlights that the adiabatic equation is applicable only for disconnection times of up to five seconds. Where a protective device takes longer, the circuit design needs to be revisited. The IET says calculating the conductor size can produce a more economical design than simply selecting a size from the tables in BS 7671.
Now, normally at this point I'd point you to a link to the article, but on this occasion I'm going to have to exercise a bit of ownership and point out that we made a video on this very subject some time ago now. Modesty prevents me from saying which member of the team made it, but you'll find the link to that video in the show notes along with the free electrical design CPD that it forms a part of.
Go and check it out. It's some really helpful content.
To end 2026, Scotland is a go for the UK's favourite five-star scrap collection service. Greencable is now fully up and running across Glasgow, Edinburgh and surrounding regions, making it easier for even more electricians and trades to get rid of waste cable and non-ferrous scrap without having to make a trip to the scrapyard.
Simply fill your Greencable container, book a collection and they'll come to you, weigh everything and pay you directly. With almost 5,000 customers now using the innovative service and over 13,000 successful scrap collections to date, these guys are the go-to for cashing in on your scrap copper cables.
So whether you're clearing cable from sites, emptying the van at home or just fed up with messy scrapyard runs, Greencable is making the whole process a whole lot simpler. Click the link in the show notes to sign up today, open your free account and arrange the delivery of your container of choice.
Now, how many times do you put down and pick up the same tool during a working day? A newly patented system from Latvian manufacturer MUKA aims to cut out some of that wasted movement by keeping frequently used tools attached, close at hand and ready for the next job. Unlike a conventional fixed tool lanyard, MUKA uses a retractable mechanism.
The unit attaches to a belt, harness or tool pouch with the tool connected to a hook at the end of a cable. Pull out the tool and use it normally. When you let go, the mechanism retracts the cable and returns the tool to an accessible position beside you.
The idea is to avoid repeatedly putting tools down, rummaging in a pouch or reaching for them again: Small interruptions that can add up over the course of a day. It also keeps the cable under control between uses rather than leaving a length of loose lanyard hanging from the user.
The system is available in standard and pro versions, both designed for tools weighing up to 3 kg. MUKA says the system is suitable for everything from routine electrical installation and workshop tasks to work inside cabinets, plant rooms and confined spaces.
It can also be used on ladders and for overhead work such as solar panel installs where preventing accidental tool drops becomes an additional benefit. The company says testing and feedback from professional users suggests that in suitable repetitive applications, workflow efficiency could improve by as much as 30%, although results will depend on the task and the user. MUKA describes its product as the world's first patented retractable tool lanyard system of its kind.
Now to lighting and a flexible LED light which is designed to bring continuous lighting into furniture, shelving, and kitchen cabinets. It measures just 3 mm wide and 6 mm high so it will fit into the tightest spaces. The Tagra Joinery Series Micro 3, supplied by Ultra LEDs, uses a flexible silicone body containing 240 LEDs per metre to produce a continuous line of illumination without visible spotting.
The 24 V product has a power consumption of 9.9 W per metre and delivers up to 270 lumens per metre, with a colour rendering index above 90 and a 120-degree beam angle. Its horizontal-bend construction allows it to follow curves in one plane, while Cut Anywhere technology allows installers to tailor the strip to the required length. Rated IP54, the flex is suitable for indoor applications where protection against dust and moisture is needed.
It's dimmable and available in colour temperatures from 2,300 K to 6,000 K, depending on the version. The five-metre kit includes connection cables, end caps, silicone adhesive and mounting brackets. It requires a compatible 24 V LED driver and comes with a five-year warranty.
Now, how about this for a bright idea? It's the Paul Russells' Lamp of the Week.
This week we've got a GLS lamp with a twist. It features four canted filaments in a warm white which gives the cosy glow of an incandescent but with the energy savings of LED. It has an Edison screw base and gives out over 800 lumens for an input power of just 3.8 W.
The rated lifetime is 50,000 hours. That's just about the time you have to wait for Gordon to return those pliers that you loaned him. You can see the full range of lamps at paulrussells.com.
And now it's time to celebrate the next generation of electricians with our Learner of the Week, proudly sponsored by Dovetail and Slate.
Fancy a new challenge and want to help the future of the industry? Why not make the jump to teaching? Dovetail and Slate are ready and waiting to help you make the leap to a better pension, generous holidays, and the chance to inspire the next generation.
This week's eFIXX Learner of the Week is Warren Harvey, who's a Level 2 student at Riverside College in Widnes. He's got a LinkedIn account where he shows off his impressive practical work and plenty of eFIXX CPD certificates. Congratulations on all you've achieved, Warren. We're looking forward to welcoming you into the trade.
Warren is keen to become an apprentice for an electrical contracting company, so if you're in the market for an apprentice and you're in the area, why not give him a chance? Congratulations, Warren. You're the eFIXX Learner of the Week in association with Dovetail and Slate.
And now to the lighter side of the electrical news. Yes, it's time for a tea break with Quickwire and its range of incredibly rapid electrical connectors.
The latest debate to go viral on the internet concerned something that doesn't hit the headlines very often: the location of electric hand dryers in public toilets. The issue has gone to the top of the online agenda thanks to a campaign by would-be politician Count Binface. He's the intergalactic traveller who regularly contests elections against the likes of Boris Johnson and Nigel Farage.
One of Binface's key policy pledges is to fix what he calls the disgraceful location of the dryer in the gents' toilet at the Crown & Treaty pub in Uxbridge, West London. The dryer is immediately behind anyone standing at the last urinal. The pub even signed a pledge to move it if he won the Uxbridge by-election.
Now another badly located dryer is lighting up the internet. This one's at the Great Himalayas Indian restaurant in Southport. As you can see, it's been placed in a rather awkward position for any visitor to the loo.
Official guidance is sparse. The Building Regs say that hand dryers should be positioned close to the basin so that people don't drip water across the floor. Fair enough.
The Wiring Regs, meanwhile, state that, depending on their IP rating, dryers must be kept clear of wet zones such as water sources. That leads to the question: could a chap at a urinal be considered a water source? Answers please at your convenience, obviously, in the comments below.
That's the lighter side of the news in our tea break with Quickwire and their range of incredibly rapid electrical connectors. Click the link in the description to check them out for yourself.
Now, just before we get to your favourite bit of the show where I reveal last week's challenge words and winners, we want to thank our premium partners. We couldn't make the news without you.
First up, one of our favourite new innovations here at eFIXX, especially now it's in sexy new packaging. For rock-solid fixings in flimsy materials, don't just fix it when you can ChumpFix it. And the best thing to come out of Yorkshire since stainless steel, the home of EV Ultra and other groundbreaking and quality products, it's Doncaster Cables. Click the links in the show notes to find out more about these great brands.
If you think you know the words that I've smuggled into this week's show, pop your guess into the comments. We'll take all the correct guesses and select one at random to be the winner of an eFIXX goody bag prize. Answers submitted after midnight on the Wednesday after release will not be entered into the draw.
Now let's reveal the winners of last week's challenge word competition. Last week's words were recalcitrant and flatulence. And the first person to come out of our electronic hat was robertsmall1715. So well done to you, Robert. Make sure you click the get involved link in the show notes to claim your prize.
And now it's time for this week's weather from Joe3PO and Fox ESS.
So, it's been a chilly week with much of the country experiencing its first ground frost of the year. And it looks like we're having another unsettled week ahead. But could we squeeze out some useful solar generation?
Before the forecast, a shout-out to this week's Fox ESS premier partner, ABE Renewables. Based in Seaford, East Sussex, they specialise in solar panels, battery storage and EV charging, helping homes and businesses make the most of their energy.
For this week's solar barometer, we're heading to Grand Avenue in Southbourne, Bournemouth. With the beach at one end and homes along the road, seems like a great place to have a bit of rooftop generation. Perhaps worth a knock on the door for anyone working in the local area.
Okay, so Tuesday it's looking unsettled with cloud and rain affecting parts of the country. Northern Ireland faces showers or longer spells of rain, while the Midlands stays generally cold with rain and some strong winds possible. Solar production could be patchy, so watch out for those brighter gaps.
Wednesday keeps that changeable theme across higher ground in North Wales, Northern England, and Scotland. There is a risk of snow during this midweek spell. Further south, temperatures edge back towards average, but that doesn't automatically mean sunnier skies.
On Thursday, Northern Ireland could see things turn drier and brighter later in the day. Elsewhere, the unsettled theme continues. So any breaks in the cloud will be welcome for solar owners.
Friday looks changeable with southern and western areas most prone to further rain or showers. Dry spells are possible between systems, but the timing is still uncertain. It's certainly a day to keep an eye on your generation app.
And into the weekend, the details are less certain. Further wet spells could mix with dry interludes with colder conditions and overnight frost still possible further north. Some useful sunshine is possible, but no promises of a bumper solar weekend.
So November sunshine might work short hours, but we can still make those hours count. Charge at the cheaper rate and make the most of any solar that offers some generation. And that's your weather.
Thanks for that update, Joe.
This week, we've been lit by Flex7 with their lightning-fast, pre-wired modular lighting connection system that keeps your installation times razor sharp. Don't forget to click the links in the show notes to find out more.
Thanks for listening to this episode of Electrical News Weekly. Until next time, have a great week. Stay safe out there and remember, there's no such thing as a torque-calibrated arm.